{"product_id":"apc-power-saving-back-ups-rs-1200-230v-cee-75-1","title":"APC Power Saving Back-UPS RS 1200 230V CEE 7\/5","description":"\u003cdiv id=\"icepim-bulletpoints\"\u003e\u003cul\u003e\n\u003cli\u003eLine-Interactive\u003c\/li\u003e\n\u003cli\u003e1.2 kVA 720 W\u003c\/li\u003e\n\u003cli\u003eSealed Lead Acid (VRLA)\u003c\/li\u003e\n\u003cli\u003eBlack\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/div\u003e\u003cdiv id=\"icepim-long-desc\"\u003e\u003cp id=\"ice_long_description\"\u003eThe Back-UPS RS offers high performance protection for your business and office computer systems. It provides abundant battery backup power, allowing you to work through medium and extended length power outages. It also safeguards your equipment from damaging surges and spikes that travel along utility, phone and network lines. A distinguishing feature of the Back-UPS RS is automatic voltage regulation (AVR). AVR instantly adjusts both low and high voltages to safe levels, so you can work indefinitely during brownouts and overvoltage situations, saving the battery for power outages when you need it most. Award-winning shutdown software automatically powers down your computer system in the event of an extended power outage. Additional features like audible alarms, LED status indicators, user replaceable battery, push-button circuit breakers and plentiful outlets (including transformer-block spaced outlets) make the Back-UPS RS the perfect unit to protect your business' productivity from the constant threat of power problems and lost data. \u003cbr\u003e\u003cbr\u003e\u003cb\u003eGreen mode: \u003c\/b\u003ePatent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eAudible alarms: \u003c\/b\u003eProvide notification of changing flywheel conditions\u003cbr\u003e\u003cbr\u003e\u003cb\u003eBattery failure notification:\u003c\/b\u003e Provides early-warning fault analysis on batteries enabling timely preventive maintenance\u003cbr\u003e\u003cbr\u003e\u003cb\u003ePower-saving outlets: \u003c\/b\u003e Automatically cuts power to idle equipment to conserve electricity.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eLCD display:\u003c\/b\u003e Alpha-Numeric Display which displays system parameters and alarms.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eBattery-protected and surge-only outlets: \u003c\/b\u003e Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment\u003cbr\u003e\u003cbr\u003e\u003cb\u003eCold-start capable: \u003c\/b\u003e Provides temporary battery power when the utility power is out.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eHot-swappable batteries:\u003c\/b\u003e Ensures clean, uninterrupted power to protected equipment while batteries are being replaced\u003cbr\u003e\u003cbr\u003e\u003cb\u003eAutomatic self-test: \u003c\/b\u003ePeriodic battery self-test ensures early detection of a battery that needs to be replaced.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eAdjustable voltage sensitivity: \u003c\/b\u003eProvides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eAudible alarms:\u003c\/b\u003e Provides notification of changing utility power and UPS conditions.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eUser-replaceable batteries:\u003c\/b\u003e Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)\u003cbr\u003e\u003cbr\u003e\u003cb\u003eUSB connectivity:\u003c\/b\u003e Provides management of the UPS via a USB port (not available on all models).\u003cbr\u003e\u003cbr\u003e\u003cb\u003eTransformer-block spaced outlets: \u003c\/b\u003e Protect equipment with input transformer blocks without blocking access to other receptacles.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eBoost and Trim Automatic Voltage Regulation (AVR):\u003c\/b\u003e  Gives higher application availability by correcting low and high voltage conditions without using the battery\u003cbr\u003e\u003cbr\u003e\u003cb\u003eAutomatic Voltage Regulation (AVR)\u003c\/b\u003e: Gives higher application availability by correcting low and high voltage conditions without using the battery.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eIntelligent battery management\u003c\/b\u003e: Maximizes battery performance, life, and reliability through intelligent, precision charging.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eBuilding Wiring Fault Indicator: \u003c\/b\u003eThis LED informs users of potentially dangerous wiring problems in the wall circuit.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eAdjustable voltage sensitivity: \u003c\/b\u003eProvides the ability to adapt the Power Conditioner for optimal performance in specific power environments or generator applications.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eAutomatic Voltage Regulation (AVR):\u003c\/b\u003e Automatically steps up low voltage and steps down high voltage to levels that are suitable for your equipment.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eBattery fault detection: \u003c\/b\u003eMonitors room and individual battery temperature changes for early detection of thermal runaway, shorted cells, open circuit, and bad battery.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eBattery-protected and surge-only outlets:\u003c\/b\u003e Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eSafety-agency approved:\u003c\/b\u003e Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. \u003cbr\u003e\u003cbr\u003e\u003cb\u003ePower conditioning\u003c\/b\u003e: Protects connected loads from surges, spikes, lightning, and other power disturbances. \u003cbr\u003e\u003cbr\u003e\u003cb\u003eAudible alarms: \u003c\/b\u003eProvides notification of changing utility power and UPS conditions. \u003cbr\u003e\u003cbr\u003e\u003cb\u003eAutomatic restart of loads after UPS shutdown:\u003c\/b\u003e Automatically starts up the connected equipment upon the return of utility power. \u003cbr\u003e\u003cbr\u003e\u003cb\u003eAutomatic self-test: \u003c\/b\u003ePeriodic battery self-test ensures early detection of a battery that needs to be replaced.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eBattery replacement without tools: \u003c\/b\u003eAllows quick, easy battery replacement. \u003cbr\u003e\u003cbr\u003e\u003cb\u003eLED status indicators:\u003c\/b\u003e Quickly understand unit and power status with visual indicators. \u003cbr\u003e\u003cbr\u003e\u003cb\u003eCold-start capable:\u003c\/b\u003e Provides temporary battery power when the utility power is out. \u003cbr\u003e\u003cbr\u003e\u003cb\u003eHot-swappable batteries:\u003c\/b\u003e Ensures clean, uninterrupted power to protected equipment while batteries are being replaced \u003cbr\u003e\u003cbr\u003e\u003cb\u003eResettable circuit breakers: \u003c\/b\u003e Enables a quick recovery from overload events. \u003cbr\u003e\u003cbr\u003e\u003cb\u003eTransformer-block spaced outlets:\u003c\/b\u003e Protect equipment with input transformer blocks without blocking access to other receptacles. \u003cbr\u003e\u003cbr\u003e\u003cb\u003eUser-replaceable batteries: \u003c\/b\u003e Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) \u003cbr\u003e\u003cbr\u003e\u003cb\u003eAdjustable voltage sensitivity: \u003c\/b\u003eProvides the ability to adapt the UPS for optimal performance in specific power environments or generator applications. \u003cbr\u003e\u003cbr\u003e\u003cb\u003eAdjustable voltage-transfer points: \u003c\/b\u003eMaximizes useful battery life by widening the input voltage window or tightening the output voltage regulation. \u003cbr\u003e\u003cbr\u003e\u003cb\u003eIntelligent battery management: \u003c\/b\u003eMicro-processor controlled battery charging and diagnostic testing ensures maximum battery life.\u003c\/p\u003e\u003c\/div\u003e\u003cdiv id=\"icepim-pdf-urls\"\u003e\u003cul\u003e\u003cli\u003e\u003ca href=\"https:\/\/cdn.iceshop.nl\/objects\/mmo_6859277_1765269779_621_2082466.pdf\" target=\"_blank\"\u003emanual pdf\u003c\/a\u003e\u003c\/li\u003e\u003c\/ul\u003e\u003c\/div\u003e","brand":"APC","offers":[{"title":"Default Title","offer_id":59801282904145,"sku":"BR1200G-FR","price":427.41,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0975\/0036\/4881\/files\/c6eec3a5c3d1a527784d03f3a16a75b3.jpg?v=1784028555","url":"https:\/\/backtotheoffice.ie\/products\/apc-power-saving-back-ups-rs-1200-230v-cee-75-1","provider":"Back to the Office Ireland","version":"1.0","type":"link"}